SNDC

Heating and Air-conditionig Equipement manufacturer
Thermal comfort and air quality

Electrical air conditioner

 

| SKIMO Plus | Efficient | Compact | Reliable | Adaptable | Data sheet | FAQ |

 

SKIMO Plus air conditioning system perforfance

Tests and technical testing

Like all of the products in this range, the SKIMO Plus air conditioning system has been subject to a wide variety of tests. Every SKIMO Plus air conditioning system has been through verification procedures in order to validate its performance.

Test conditions

A/C tests

 

The SNDC testing laboratory reproduces the exterior temperature and sunlight. SKIMO Plus has been tested at 3 temperature levels in a 4m³ cab :

  • An exterior temperature of 35°C over a period of 60 minutes.
  • An exterior temperature of 45°C over a period of 60 minutes.
  • An exterior temperature of 55°C over a period of 60 minutes.

The SKIMO Plus air conditioning system only starts up when the interior temperature of the test cab has been stabilised. Throughout the tests, the cab is exposed to an average simulated solar energy of 600W/m², measured by a pyranometer. The air conditioning system is supplied by a continuous current of 24V.

 

 

 

SKIMO in hot environment

Skimo in test room

measure analysis

 

 

How to read the readings

The readings are taken from a data acquisition centre fitted with calibrated atmospheric PT100 thermocouple type probes, accurate to 0.1°C.

Performances measured

At an exterior temperature of +35°C, after 5 minutes testing we obtained a diffuser outlet temperature of +10,4°C for an ambient cab temperature of +23,3°C. After an hour, the lowest temperature taken was +22,5°C. The average energy consumption of the SKIMO Plus unit was 55A.

Test: SKIMO Plus 24V at 35°C

 

At an exterior temperature of +45°C, after 60 minutes testing we obtained a diffuser outlet temperature of +6,4°C for an ambient cab temperature of +27,3°C. The average energy consumption of the SKIMO Plus unit was 69A.

Performances températures SKIMO

At an exterior temperature of +55°C, after 60 minutes testing we obtained a diffuser outlet temperature of +14,3°C for an ambient cab temperature of +33,5°C. The average energy consumption of the SKIMO Plus unit was 88,9A.

 

Test: SKIMO Plus 24V at 55°C