SKIMO 12V DC or 24V DC Electrical HVAC UnitSNDC - ECOCLIM

 | About SNDC |Contact  

SKIMO 80V data sheet

 

Main featuresdimensions of SKIMO ceiling panel

SKIMO is a self contained air conditioning with: air conditioning components (condenser, evaporator, drying filter, compressor …), electrical components (electrical motor, fan, blower, harness, fuses), and a ceiling panel with controls and air outlets.

 

  • dimensions of SKIMO unitDimensions of the unit: length 72 cm, width 48 cm, height 25 cm (28 ½’’ x 19’’ x 10’’)
  • Dimensions of the ceiling panel: length 30 cm, width 40 cm, height 6 cm (12’’ x 15 ¾’’ x 2 2/5’’).
  • Weight 27 kg
  • Cooling power of the evaporator: 2900 W for air intake at +31°C with 50% humidity. Refer to test reports (page: Technical Information)
  • Maximum electrical consumption: 10A (80V DC) 30°C – 12A (80V DC) 43°C.
  • Position: horizontal
  • Surface of flat roof necessary for installation: 30 cm x 40 cm. SKIMO reinforced structure enables a cantilevered installation. The maximum cantilever distance is 25cm (10’’)
  • SKIMO can be installed with a pitch angle of 25° and a roll angle of 45°

/!\ Nota : SKIMO 80V has some components which need 12VDC power supply (fan, blower). It is necessary to check if there is or not a 12VDC power supply able to deliver 12 Amps (150W) on the vehicle. If it is not the case, an optional converter 80V/12V (300W) should be used.

Safety features

SKIMO includes 7 safety functions:

Low voltageLow voltage

Should the vehicle battery go below a threshold of 70 V (for a 80 V SKIMO unit), the unit will automatically shut down. This feature prevents from emptying the battery and saves enough battery for starting the engine of the vehicle.

OvervoltageOvervoltage

Should the battery voltage reach a threshold of 100 V (for a 80 V SKIMO unit), the unit will automatically shut down.

Overheat Overheat 

The unit automatically shuts down in case of overheat of its electrical motor. It will start again only after the temperature has gone down.

OverconsumptionOverconsumption

An abnormal consumption of SKIMO will shut the system down.

Overpressure or low pressureOverpressure or low pressure

SKIMO is equipped with a pressure switch which protects the system in case of overpressure or low pressure.

Compressor securityCompressor security

The compressor is equipped with a pressure safety which protects the system in case of failure of the pressure switch

Operator safetyOperator safety

KIMO cover safety switch shuts the electrical motor down when the operator removes the cover.

 

 

!\ Notice: after a shut down of the system, SKIMO must be switched off and then on again. A safety shut down should occur rarely. In case of repetitive safety shut down, please contact a specialist.

 

 